PRODUCT


LTS-ICP6800 Inductively Coupled Plasma Emission Spectrometer Standard


Inductively Coupled Plasma Emission Spectrometer (ICP) is the main light source used in automatic emission spectroscopy. ICP has the characteristics of ring structure, high electron density and inert atmosphere. It can be used as an excitation source with low detection limit, wide linear range, less ionization and chemical interference and high accuracy and precision.

Category:

Products

ICP

Spectrophotometer

WhatsApp:


  • Product Description
  • Company Profile
  • Packing and shipping
    • Commodity name: LTS-ICP6800 Inductively Coupled Plasma Emission Spectrometer Standard
    • Commodity ID: LTS-ICP6800

    Inductively Coupled Plasma Emission Spectrometer (ICP) is the main light source used in automatic emission spectroscopy. ICP has the characteristics of ring structure, high electron density and inert atmosphere. It can be used as an excitation source with low detection limit, wide linear range, less ionization and chemical interference and high accuracy and precision.

    Inductively Coupled Plasma Emission Spectrometer Standard

     

    Specification

    Model

    LTS-ICP6800

    RFPower technical parameter

    Circuit type:

    solid-state RF power supply,with function of automatch

    Frequency:

    27.12MHz±0.05%

    Frequency Stability:

    <0.1%

    Power Output:

    800W—1200W

    Power Output Stability:

    <0.3%

    Escaped RF radiation:

    30cm away from the instrument, electric field: E<2V/m

    Sampling System Technical Parameter

    Output working coil inner diameter:

    25mm

    Torque tube:

    Three concentric, external diameter 20mm

    Coaxial nebulizer:

    Outer diameter 6mm

    Double barrel atomizing chamber:

    Outer diameter 34mm

    Gas Flow Controls

    Plasma Argon Flowmeter:

    (100-1000)L/h(1.6-16L/min)

    Auxiliary Argon Flowmeter:

    (10-100)L/h(0.16-1.66L/min)

    Carrier Argon Flowmeter:

    (10-100)L/h(0.16-1.66L/min)

    Pressure Maintaining Valve

    (0-0.4MPa)

    Cooling Water:

    Temperature:20-25℃,Rate of Flow>5L/min, Hydraulic Pressure>0.1MPa

    Spectrometer

    Optics:

    Czerny-Turner type

    Focal length:

    1000 mm

    Grating:

    lon Beam Etching Holographic Grating,3600L/mm or 2400L/mm

    Reciprocal linear dispersion:

    0.26nm/mm

    Resolution:

    ≤0.007nm(3600 line grating); ≤0.015nm (2400line grating)

    Wavelength range:

    3600 line grating:(190nm~500) nm; 2400 line grating: (190nm~800) nm

    Minimum pace of stepping motor:

    ≤0.0006 nm

    Exit Slit:

    12um;Entrance Slit:10um

    Photoelectric Converter Performance

    Photomultiplier tube specification:

    R293/R928

    Negative HV on PMT:

    0-1000V; Stability:<0.05%

     

     

    Features

     

Message

Related Products


%{tishi_zhanwei}%