LABTEX Graphite Furnace Atomic Absorption Spectrophotometer


The atomic absorption spectrophotometer uses excellent all-band deuterium lamp background correction technology. High performance self-priming double background correction; The comprehensive and safe intelligent gas control module and the advanced lamp position eight lamp stand achieve 360 degree rotation design.

Category:

Products

Spectrophotometer

Atomic Absorption Spectrophotometer

WhatsApp:


  • Product Description
  • Company Profile
  • Packing and shipping
    • Commodity name: LABTEX Graphite Furnace Atomic Absorption Spectrophotometer
    • Commodity ID: LTS-AAS3624;LTS-AAS3628

    The atomic absorption spectrophotometer uses excellent all-band deuterium lamp background correction technology. High performance self-priming double background correction; The comprehensive and safe intelligent gas control module and the advanced lamp position eight lamp stand achieve 360 degree rotation design.

    Single Beam Graphite Furnace Atomic Absorption Spectrophotometer

    Specifications:

    Model LTS-AAS3624 LTS-AAS3628
    Optics System  Type Single Beam
    Monochromator Anaberration C-T type, focal length 350mm
    Dispersing element optical grating 1800 bars /mm, flicker wavelength 250nm
    Spectral bandwidth (nm) 0.1、0.2、0.4、0.7、1.4、2nm six grades  automatic switchover
    Wavelength range (nm)           185-900nm
    Wavelength indication error ±0.3 nm ±0.2 nm
    Wavelength repeatability (nm) ≤0.1nm
    Spectral bandwidth deviation ±0.02 nm
    Light point 4 8
    Element lamp type Ordinary element lamp
    Photometric Property  Reading mode Transmittance, absorbance, concentration
    Photometric Range 0-125%,-0.1-3.00A
    Cu static baseline drift ±0.004A/30min ±0.003A/30min
    Cu dynamic baseline shift ±0.006A/15min ±0.005A/15min
    Background correction   Deuterium lamp background correction capability >= 30x (1Abs) Deuterium lamp >= 40x (1Abs)
    Graphite Furnace Analysis Characteristic concentration Cd ≤0.9pg
    Cu≤20pg
    Cd≤0.6pg
    Cu≤20pg
    Detection Limit Cd≤1.5pg
    Cu ≤25pg
    Cd≤1.0pg
    Cu≤25pg
    Repeatability(Cd) RSD≤4% RSD≤3%
    Graphite furnace temperature range      Room temperature ~ 3000℃
    Large power temperature rise range            1500℃~3000℃
    Slope and hold time              1s~255s 1s~255s
    Heating rate Maximum heating rate 2000℃/ s
    Atomization heating method            Light-controlled heating, time-controlled heating, general heating
    Outside protective gas flow          1 L/min
    Tube protection gas flow            4 adjustable levels (0, 50, 200, 250ml/min flow)
    safety precautions      Cooling water flow, protective gas pressure, furnace body temperature, power supply temperature, graphite tube installation alarm
    Data processing  Measurement mode Graphite furnace process
    Concentration calculation method   Standard curve method (6 linear and nonlinear fitting methods), standard addition method, interpolation method
    Number of repeated measurements 1-30 times, calculate and give the mean, standard deviation and relative standard deviation of absorbance and concentration
    Report printing Parameter printing, data result printing
    Others Computer       circumscribed
    Overall dimensions 830*650*560
    Weight 110Kg
    Power           Voltage 220V±22V, frequency 50Hz ±1Hz
    Operating temperature           10℃~30℃
    Operating Humidity           40%~85%

                               Features

    1. Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument.
    2. Comprehensive and safe intelligent gas control module.
    3. Excellent full-band deuterium lamp background correction technology and high-performance self-priming dual background
    correction.
    4. Fully automatic instrument control, the light source supports high-performance element lamps, and can be quickly completed with one click.
    5. Advanced eight-position lamp holder with 360-degree rotating design.
    6. Novelly designed atomizer and intelligent lifting.
    7. Simple, professional, automatic and fully operational RG-WinAAS workstation software under MS Window system.

     
    Oil free mute vacuum compressor
    No need for engine oil lubrication, clean and environmentally friendly
     
    Multiple lamp holders
    The position of the hollow cathode lamp can be adjusted in all directions, and the instrument lamp position 4 or 8 lamp stand adopts a unique design to realize 360 degree rotation
     
    Application range of atomic absorption spectrometry
    Be committed to providing advanced technical solutions for various analytical fields
     
    Wide range of application
    Used in various fields such as metallurgy, geology, chemical industry, agriculture, medicine, and environmental protection

Message

Related Products


%{tishi_zhanwei}%