PRODUCT


LABTEX AAS Flame Atomic Absorption Spectrophotometer


The atomic absorption spectrophotometer uses excellent all-band deuterium lamp background correction technology. High performance self-priming double background correction; The comprehensive and safe intelligent gas control module and the advanced lamp position eight lamp stand achieve 360 degree rotation design.

Category:

Products

Spectrophotometer

Atomic Absorption Spectrophotometer

WhatsApp:


  • Product Description
  • Company Profile
  • Packing and shipping
    • Commodity name: LABTEX AAS Flame Atomic Absorption Spectrophotometer
    • Commodity ID: LTS-AAS3604/3608/3618

    The atomic absorption spectrophotometer uses excellent all-band deuterium lamp background correction technology. High performance self-priming double background correction; The comprehensive and safe intelligent gas control module and the advanced lamp position eight lamp stand achieve 360 degree rotation design.

    AAS Flame Atomic Absorption Spectrophotometer

     

    Specification

     

    Model

    LTS-AAS3604

    LTS-AAS3608

    LTS-AAS3618

    Optics System

    Type

    Single beam

    Single Beam

    Double Beam

    Monochromator

    Anaberration C-T type, focal length 350mm

    Dispersing element

    optical grating 1800 bars /mm, flicker wavelength 250nm

    Spectral bandwidth (nm)

    0.1、0.2、0.4、0.7、1.4、2nm six grades automatic switchover

    Wavelength range (nm)

    185-900nm

    Wavelength indication error

    ±0.3 nm

    ±0.2 nm

    ±0.15 nm

    Wavelength repeatability (nm)

    ≤0.1nm

    ≤0.1nm

    ≤0.05nm

    Spectral bandwidth deviation

    ±0.02 nm

    ±0.02 nm

    ±0.02 nm

    Light point

    4

    8

    8

    Element lamp type

    Common element lamp

    Ordinary element lamp

    Ordinary, high-performance element lamp

    Photometric Property

    Reading mode

    Transmittance, absorbance, concentration

    Photometric Range

    0-125%,-0.1-3.00A

    Cu static baseline drift

    ±0.004A/30min

    ±0.003A/30min

    ±0.002A/30min

    Cu dynamic baseline shift

    ±0.006A/15min

    ±0.005A/15min

    ±0.004A/15min

    Background correction

    Deuterium lamp background correction capability >=30 times (1Abs)

    Deuterium lamp >= 40x (1Abs)

    Deuterium lamp >= 40x (1Abs)
    Self-priming >= 80x (1Abs)

    Flame Analysis

    Characteristic concentration (Cu)

    ≤0.04ug/ml

    ≤0.035ug/ml

    ≤0.02ug/ml

    Detection limit(Cu)

    ≤0.008ug/ml

    ≤0.006ug/ml

    ≤0.004ug/ml

    Repeatability

    RSD≤1%

    RSD≤0.6%

    RSD≤0.5%

    Acetylene flow regulation

    Automatic 12 grades

    Air assisted air conditioning

    Automatic 4 grades

    Burner lift

    Automatic rising-lowering

    Burner

    Metal titanium burner

    Atomizer

    High efficiency glass atomizer

    Atomizing chamber

    Corrosion-resistant material atomization chamber

    Safety precautions

    Abnormal pressure protection of flame gas and auxiliary gas

    Data processing

    Measurement mode

    Flame method, hydride generation-atomic absorption method, flame emission method

    Concentration calculation method

    Standard curve method (6 linear and nonlinear fitting methods), standard addition method, interpolation method

    Number of repeated measurements

    1-30 times, calculate and give the mean, standard deviation and relative standard deviation of absorbance and concentration

    Report printing

    Parameter printing, data result printing

    Others

    Computer

    circumscribed

    Overall dimensions

    830*650*560

    830*650*560

    830*650*560

    Weight

    90Kg

    90Kg

    95Kg

    Power

    Voltage 220V±22V, frequency 50Hz ±1Hz

    Operating temperature

    10℃~30℃

    Operating Humidity

    40%~85%

     

     

    Feature

    1. Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument.

    2. Comprehensive and safe intelligent gas control module.

    3. Excellent full-band deuterium lamp background correction technology and high-performance self-priming dual background correction.

    4. Fully automatic instrument control, the light source supports high-performance element lamps, and can be quickly completed with one click.

    5. Advanced 360-degree rotation design of lamp position.

    6. Novelly designed atomizer and intelligent lifting.

    7. Simple, professional, automatic and fully operational RG-WinAAS workstation software under MS Window system.

     

    Oil free mute vacuum compressor
    No need for engine oil lubrication, clean and environmentally friendly
     
    Multiple lamp holders
    The position of the hollow cathode lamp can be adjusted in all directions, and the instrument lamp position 4 or 8 lamp stand adopts a unique design to realize 360 degree rotation
     
    Application range of atomic absorption spectrometry
    Be committed to providing advanced technical solutions for various analytical fields
     
    Wide range of application
    Used in various fields such as metallurgy, geology, chemical industry, agriculture, medicine, and environmental protection

Message

Related Products


%{tishi_zhanwei}%