LTA-HA Horizontal Cylindrical Pressure Steam Sterilizer Simple Type
★The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can't be start on if the door doesn't close well.
★The safety value will be open automatically when the inner pressure over 0.24MPa,and the steam be exhausting to the water tank.
★The power will be cut-off automatically,cut-off the water and alarm when the machine lacking water.
★The chamber of the sterilizer is made of stainless steel.
Category:
Horizontal Type
Pressure Steam Sterilizer
Autoclave Sterilizer
WhatsApp:
- Product Description
- Company Profile
- Packing and shipping
-
- Commodity name: LTA-HA Horizontal Cylindrical Pressure Steam Sterilizer Simple Type
- Commodity ID: LTA-HA
<br/>★The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can't be start on if the door doesn't close well.<br/>★The safety value will be open automatically when the inner pressure over 0.24MPa,and the steam be exhausting to the water tank.<br/>★The power will be cut-off automatically,cut-off the water and alarm when the machine lacking water.<br/>★The chamber of the sterilizer is made of stainless steel.
LTA-HA Horizontal Cylindrical Pressure Steam Sterilizer Simple Type
The horizontal pressure sterilizer adopts the gravity displacement method to eliminate thecold air in the inner chamber, so that the content of cold air in the inner chamber steam is less and the sterilization is more reliable. At the same time, in the sterilization process of the equipment, the control system automatically adjusts the inletsteam and exhaust steam according to the temperature of the inner chamber. It is mainly used in hospital supply rooms, operatingrooms, pharmaceutical factories and laboratories of scientific research institutions for sterilization of cloth articles, surgicalinstruments and utensils for medical and experimental purposes
Feature1. Sterilizing course automatic sterilization controlled,easy to operate.
2. With drying function,suitable dressing drying.
3. With over-temperature,over-pressure auto-protect device.
4. The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can't be start on if the door doesn't close well.
5. The safety value will be open automatically when the inner pressure over 0.24MPa,and the steam be exhausting to the water tank.
6. The power will be cut-off automatically,cut-off the water and alarm when the machine lacking water.
7. The chamber of the sterilizer is made of stainless steel.Parameter
Technical Data
LTA-150HA
LTA-200HA
LTA-280HA
LTA-400HA
LTA-500HA
Sterilizing Chamber
Volume150L
φ440×1000mm
200L
φ515×1000mm
280L
φ600×1000mm
400L
Φ700×1100mm
500L
Φ700×1300mm
Working Pressure
0.22MPa
Working Temperature
134℃
Adjustment of Temperature
105℃ - 134℃
Time of Sterilization
0-60 min
Time of drying
0-60 min
Heat Average
≤±2℃
Power
9KW/380V 50Hz
9KW/380V 50Hz
12KW/380V 50Hz
18KW/380V 50Hz
18KW/380V 50Hz
Dimension
1400×600×1300
1400×670×1650
1400×770×1780
1430×880×1830
1800×900×1820
Transport dimension
1550×750×1850
1560×820×1850
1680×920×2100
1600×1050×2100
1850×1050×2100
G.W/N.W
320/240 KG
350/260 KG
465/365 KG
530/420 KG
580/470 KG